ATM_ID: 5EA91D5C-96D6-11E7-8680-23498E4AD280 MFF:
PLANNEDTIMESTAFF: 1 ID: DPQA_Regression_SYSTEM/Testcases/FS_22.080_Software_Upgrade/102617 TESTCASE_HEADLINE: To check if the EIP apps, Weblets and their data settings are retained upon Altboot upgrade. GROUP: accounting FEATURE: copy_auditron SUB_FEATURE: INPUT:1) In CWIS page login as Admin -> Navigate to Properties -> Apps -> Custom Apps -> Weblet Management -> Choose and Install the "LocalStorageTest" Weblets.
2) Go to device LUI -> Select "LocalStorageTest" Weblet -> In Weblet click on "Click me!" button 15 times -> The clicked count saved as "15 times" in the device local storage.
3) Now wait till 12.15AM [Atleast need to wait 15 mints for creating Clone to Self file] in the mid night for clone to self creation. (or) go to CWIS page login as admin -> Properties -> General Setup -> Date and Time -> Set the Manual time to 11.50 PM and wait till 12.15 AM for clone to self creation in the device.
4) Make sure the device has created a Clone-to-Self file.
[In CWIS -> Properties -> General Setup -> Backup & Restore Settings -> Validate the Clone to Self creation. The Clone to self file shall be updated daily at 12:00 AM]
1) Perform Altboot upgrade in the MFP after clone to self file is created.
2) Upon completion of upgrade open the EIP apps/Weblets and check if the previously installed and modified data settings are retained. (e.g. After upgrade open the LocalStorageTest weblet and check the clicked count "15 times" shall be retained).
The previously installed EIP apps/ Weblets and their data settings should be retained even after the Altboot upgrade in the device.
PROCESS: PRIORITY: 1 TEST_TYPE: manual LOE: SKILL_SET: basic TEST_CASE_TYPE: regression TESTCASE_SOURCE: functional_spec SPEC: FS 22.080 Software Upgrade FS 51.014 EIP Weblets FS 51.044 EIP Integration SPEC_VERSION: V 1.0095 V 1.0227 V 1.0008 SPEC_TAG: [22.080.1367] (FT-21229) [D4.0-*] The EIP apps, weblets and their settings shall be part of device clonetoself settings. [22.080.1367.001] (FT-21229) [D4.0-*] The EIP apps, weblets and their settings shall be saved and automatically restored across all software upgrade methods except Forced Altboot. During Forced Altboot these settings are saved but not automatically resorted to the device, customer/user can manually restore the settings via the Revert to Previous Settings tool. [51.014.097.04] (FT-21229) [D4.0-*]Weblets and associated data (i.e. any files created on the device by the weblet) NA NA /Properties/Services/Custom Services/ Weblet Management No Yes 51.044.008.007](FT-21229) [D4.0-*] EIP Apps and associated data -> [Location - CWIS/Properties/Apps/Display (Show/Hide)], [Cloning - No], [Enhanced Cloning (Clone to self) - Yes ] ATM_OWNER: USWU53515 APPROVED_QE: APPROVED_SE: APPROVED_SPAR: TESTCASE_VERSION: TESTCASE_STATE: TESTCASE_PLATFORM: TESTCASE_PRODUCT: TESTCASE_APPROVALS: CDATE: 1505123311 MDATE: 1505123311, 1505137469, 1506322425, 1522674681 MUSER: USWU53515, USWU53515, USWU53515, q4BVX0J1 AUTHOR: USWU53515 ATM_MCOMMENTS: Imported from spreadsheet, Mapped Requirement , ., Renamed from "DPQA_NewFeature/D4.0/FT-21229_R1275_EIP_Persistent_Application_Data_across_Upgrades_to_4.0/102617". HISTORY: ATM_LOCKED: ATM_REQLINK: 0DFE2E3E-87D5-11E7-B3A4-B5EFD40A4651, 0DFED6D6-87D5-11E7-B3A4-B5EFD40A4651, E59630CC-AA93-11E7-8F06-5812DA9C2645, A0E5080C-B97C-11E7-8F5B-FC6BF7B6F312 ATM_REQCOUNT: 4 QA_TEAM: TC_WEIGHTAGE: 2 FILENAME: FILEDESC: FILES: TRAINING: ASSOCIATED_TESTCASES: RESOURCE_HW: RESOURCE_CONSUMEABLES: RESOURCE_MEDIA: APPROVE_QE: USWU53981 APPROVE_SE: USWU53981