ATM_ID: BE30B338-9D26-11E7-B780-3FFD2D2343F6 MFF: PLANNEDTIMESTAFF: ID: DPQA_Regression_SYSTEM/Testcases/FS_22.081_SW_Versioning/102717 TESTCASE_HEADLINE: To validate the TT(Train car )Id in D3.7 System software vesion GROUP: FEATURE: SUB_FEATURE: INPUT: MFD with latest WPAT D3.7 build is required. PROCEDURE: 1. Navigate to CWIS->Properties->Configuration report. 2. Select 'Software versions'and check the Device Software version. 3. Print the Configuration report and check the System Software Version in it. 4. In LUI, select Device->About option. Check the software version displayed. 5. In LUI, enter into Diagnostics and select service information. 6.Select DC 108 software version and check the System Software Version in it. 7. Launch MIB browser and connect the MFD. 8. Walk the OID 1.3.6.1.2.1.1.1 (sysDescr)and ckeck the Software Version displayed. 9.Walk the OID 1.3.6.1.2.1.25.6.3.1.2(HrSwInstalled Table) and Check the Xerox System Software displayed OUTPUT: For D3.7 the TT id should be '05' where ever the software version is displayed . Ex (AAa.PPP.TTy.DDDRR) as (101.008.047(TTy).20000) PROCESS: PRIORITY: TEST_TYPE: LOE: RESOURCE_HW: RESOURCE_CONSUMEABLES: RESOURCE_MEDIA: SKILL_SET: TEST_CASE_TYPE: TESTCASE_SOURCE: SPEC: FS 22.081 Software Versioning SPEC_VERSION: 1.0116000000000001 SPEC_TAG: [22.081.023] (FT-17749) [D3.5-*] [SPI 1.0] [+Sky] [+Sn] The System Software Set Version number will follow the following format ATM_OWNER: APPROVE_QE: APPROVED_QE: APPROVE_SE: APPROVED_SE: APPROVE_SPAR: APPROVED_SPAR: ASSOCIATED_TESTCASES: TRAINING: TESTCASE_VERSION: TESTCASE_STATE: TESTCASE_PLATFORM: TESTCASE_PRODUCT: TESTCASE_APPROVALS: CDATE: 1505817538 MDATE: 1505817538, 1532949314 MUSER: USWU53890, q4BVX0J1 AUTHOR: USWU53890 ATM_MCOMMENTS: Imported from spreadsheet, Renamed from "DPQA_Regression_SYSTEM/Testcases/FS_22.081_SW_Versioning/FS_22.081_test_change_CQGbl01164734/102717". HISTORY: ATM_LOCKED: ATM_REQLINK: 238C9CDF-6E13-1014-835A-F2A756619FB6 ATM_REQCOUNT: 1 QA_TEAM: TC_WEIGHTAGE: FILENAME: FILEDESC: FILES: