ATM_ID: BF692050-C904-11E7-9EAC-6391A5FB8F22 MFF: PLANNEDTIMESTAFF: ID: DPQA_Regression_SYSTEM/Testcases/FS_33.071_Timeouts/104707 TESTCASE_HEADLINE: Check if the System Timeout timer is reset after the last image for a build job is scanned. GROUP: FEATURE: SUB_FEATURE: INPUT: MFD without any error condition is required. PROCEDURE: 1. Log in as admin in LUI. 2. Navigate to Device > Tools > Device Settings > Timers > System Timeout, set the value as 0 min and 15 sec, and enable the warning screen. 3. Press Home button to return to Home app screen. 4. Placing more than 20 sheets in DADF, select any app like Copy, Email, Fax, etc. and program a build job with multiple segments. 5. While scanning the documents, check if the System Timeout warning screen does not display. 6. After the last sheet of the last segment is scanned, wait for 15 sec to check if the System Timeout warning screen is displayed. OUTPUT: While scanning the documents. the System Timeout warning screen should not be displayed. The timer should reset after the last sheet of the last segment is scanned. PROCESS: PRIORITY: TEST_TYPE: LOE: RESOURCE_HW: RESOURCE_CONSUMEABLES: RESOURCE_MEDIA: SKILL_SET: TEST_CASE_TYPE: TESTCASE_SOURCE: SPEC: FS 33.071 Timeouts SPEC_VERSION: v1.0016 SPEC_TAG: [33.071.001.4] (FT-14212) System Timeout timer is reset after the last image for a job or job segment is scanned. ATM_OWNER: APPROVE_QE: APPROVED_QE: APPROVE_SE: APPROVED_SE: APPROVE_SPAR: APPROVED_SPAR: ASSOCIATED_TESTCASES: TRAINING: TESTCASE_VERSION: TESTCASE_STATE: TESTCASE_PLATFORM: TESTCASE_PRODUCT: TESTCASE_APPROVALS: CDATE: 1510640788 MDATE: 1510640788 MUSER: USWU53890 AUTHOR: USWU53890 ATM_MCOMMENTS: Imported from spreadsheet HISTORY: ATM_LOCKED: ATM_REQLINK: CDDB1E55-8765-1014-BC09-9AEF04CB26D8 ATM_REQCOUNT: 1 QA_TEAM: TC_WEIGHTAGE: FILENAME: FILEDESC: FILES: