PRIORITY: TEST_TYPE: APPROVED_QE: INPUT: Ensure the USB ports are enabled in the device. FILES: TESTCASE_HEADLINE: To verify the time taken for the upgrade does not exceed 45 minutes TESTCASE_VERSION: AUTOMATABLE_NOTAUTOMATABLE: FEATURE: APPROVE_SE: SPEC_VERSION: 1.0115. MFF: TESTCASE_PLATFORM: SPEC: [22.080.016] (FT-14502) CCSFEAT21047 CQ507077 [D2.3-*] HISTORY: DATA_LOGIC: CDATE: 1544078998 TESTCASE_APPROVALS: TESTCASE_STATE: OUTPUT: Upgrade time should not exceed more than 45 minutes. FILEDESC: PROCESS: RESOURCE_HW: TC_WEIGHTAGE: APPROVED_SPAR: MDATE: 1544078998 SKILL_SET: TESTCASE_SOURCE: TEST_CASE_TYPE: APPROVE_QE: APPROVED_SE: PLANNEDTIMESTAFF: ATM_OWNER: AUTHOR: W44npx4w IMPLEMENTED: LOE: ASSOCIATED_TESTCASES: ATM_REQLINK: 16C10F14-F3EF-11E8-98D2-317FCDD1F86B TRAINING: GROUP: MUSER: W44npx4w SUB_FEATURE: SPEC_TAG: The time taken to program all platforms shall not exceed 45 minutes (excluding variable factors).  PROCEDURE: 1. Upgrade the device using Forced Altboot method. 2. Once the device enters Software upgrade screen start the timer. 3. Stop the timer once all the modules upgraded and the progress shows 100%. The variable factors include: • The time taken for the machine to enter upgrade mode • The time taken to transfer the files from the PC via USB to the machine • The time taken to transfer an upgrade file across the network to the Network Controller Disk • Processing (file extraction) time on the machine • Machine reboot time after the upgrade • Disk Encryption RESOURCE_CONSUMEABLES: ATM_LOCKED: 0 APPROVE_SPAR: TESTCASE_PRODUCT: QA_TEAM: FILENAME: ATM_ID: 2599F422-F923-11E8-BC3E-DA5C2412F61E ATM_MCOMMENTS: Copied from "PUQE-CFT_Atlantis_2.0M/Corvo/FS_22.080_Software_upgrade/Common_Testcases/38079". RESOURCE_MEDIA: ATM_REQCOUNT: 1