PRIORITY: 1

TEST_TYPE: manual

APPROVED_QE: approved

INPUT: 1. Make sure "Software Upgrade Security Installation Policy" is enabled
2. In D3.7 MFP, Set the user defined values to energy saver timers (example: low power to 10 and sleep to 5)
3. Configure the email app with valid SMTP settings (example:smart.com), configure the default workflow scanning with necessary FTP server details
4. Upgrade the MFP from D3.7 to D4.0 via WEBUI method
5. Change the user defined values to energy saver timers (example: low power to 25 and sleep to 10)
6. Change the email app with valid SMTP settings(example:cat.com), configure the default workflow scanning with necessary SMB server details

FILES:

TESTCASE_HEADLINE: To validate the previous D3.7 settings are retained automatically while downgrading the MFP from D4.0 release to D3.7 release via WEBUI method.

TESTCASE_VERSION:

AUTOMATABLE_NOTAUTOMATABLE: not_reviewed

FEATURE:

APPROVE_SE: w4y5hbch

SPEC_VERSION:

MFF:

TESTCASE_PLATFORM:

SPEC: [22.080.1543] (FT-22840) [D4.0-*]  [22.080.1543.001] (FT-22840) [D4.0-*]

HISTORY:

DATA_LOGIC: logic

CDATE: 1544079013

TESTCASE_APPROVALS:

TESTCASE_STATE: ready_to_test

OUTPUT: <p>1. Software downgrade should be completed successfully. 2. MFP should be retained and come up with D3.7 backup settings automatically (Example: Energy saver time of low power mode to 10</p>, <p>sleep mode to 5</p>, <p>Email app with SMTP settings and default workflow scanning with FTP server details</p>, 

FILEDESC:

PROCESS:

RESOURCE_HW:

TC_WEIGHTAGE: 2.6

APPROVED_SPAR: approved

MDATE: 1544079013

SKILL_SET: intermediate

TESTCASE_SOURCE:

TEST_CASE_TYPE: full_test

APPROVE_QE: w4y5hbch

APPROVED_SE: approved

PLANNEDTIMESTAFF:

ATM_OWNER: w4y5hbch

AUTHOR: W44npx4w

IMPLEMENTED: yes

LOE: 60

ASSOCIATED_TESTCASES:

ATM_REQLINK: 17ABDE18-F3EF-11E8-98D2-317FCDD1F86B, 17ACA280-F3EF-11E8-98D2-317FCDD1F86B

TRAINING:

GROUP: device_preparation

MUSER: W44npx4w

SUB_FEATURE:

SPEC_TAG:   [22.080.1543] (FT-22840) [D4.0-*] During a SW upgrade to release with higher architecture code (“AAa”), if the revert to previous settings file or the backup file from midnight was created is the same SW version as the desired downgrade version, then a copy of that file will be preserved with a filename that contains the architecture code it was created with.    [22.080.1543.001] (FT-22840) [D4.0-*] During SW downgrade to release with lower architecture code (“AAa”) using customer upgrade methods and Altboot, and a backup file exists that contains the lower architecture code, then device shall automatically restore this backup file.  

PROCEDURE: <p>1. In CWIS</p>, <p>Login as admin 2. Click on the Properties tab-&gt; General setup-&gt; Configuration File Management-&gt; Install Files-&gt; Software -&gt; Select Manual Upgrade. 3. Browse and select the D3.7 DLM file and click Install Software. 4. Wait to see the File Loaded successful message then close it 5. Check in the LUI</p>, <p>Upgrade module start and end successfully. 6. Once the MFP is ready state</p>, <p>check the confirmation (1 and 2)</p>

RESOURCE_CONSUMEABLES:

ATM_LOCKED: 0

APPROVE_SPAR: w4y5hbch

TESTCASE_PRODUCT:

QA_TEAM:

FILENAME:

ATM_ID: 2ECD697A-F923-11E8-BC3E-DA5C2412F61E

ATM_MCOMMENTS: Copied from "PUQE-CFT_Atlantis_2.0M/Corvo/FS_22.080_Software_upgrade/Common_Testcases/38498".

RESOURCE_MEDIA:

ATM_REQCOUNT: 2