PRIORITY: 1

TEST_TYPE: manual

APPROVED_QE: approved

INPUT: 1. Make sure the USB Port Security is enabled for Rear and Front USB Ports
2. In D3.7 MFP, Set the user defined values to energy saver timers (example: low power to 10 and sleep to 5)
3. Configure the email app with valid SMTP settings (example:smart.com), configure the default workflow scanning with necessary FTP server details
4. Change the MFD time to 11.45 PM for midnight clone file creation.
5. Once the MFD time is 12.15 AM, check whether clone to self file is created in file zilla/teraterm by using the below path/commands.
(var/opt/nc/dlms/upgrade/data/clone_self).
6. Upgrade the MFP from D3.7 to D4.0 via Non-Forced Altboot method
7. The energy saver timers, Email app and Default workflow scanning settings are reverted back to Default settings
8. Change the MFD time to 11.45 PM for midnight clone file creation.
9. Once the MFD time is 12.15 AM, check whether clone to self file is created in file zilla/teraterm by using the below path/commands.
(var/opt/nc/dlms/upgrade/data/clone_self).

FILES:

TESTCASE_HEADLINE: To validate the previous D3.7 settings are retained automatically after downgrading the MFP from D4.0 release to D3.7 release via Altboot

TESTCASE_VERSION:

AUTOMATABLE_NOTAUTOMATABLE:

FEATURE:

APPROVE_SE: w4y5hbch

SPEC_VERSION:

MFF:

TESTCASE_PLATFORM:

SPEC: [22.080.1543] (FT-22840) [D4.0-*]  [22.080.1543.001] (FT-22840) [D4.0-*]

HISTORY:

DATA_LOGIC: logic

CDATE: 1544079014

TESTCASE_APPROVALS:

TESTCASE_STATE: ready_to_test

OUTPUT: <p>1. Software downgrade should be completed successfully. 2. Instead of default settings MFP should be retained and come up with D3.7 backup settings automatically (Example: Energy saver time of low power mode to 10</p>, <p>sleep mode to 5</p>, <p>Email app with SMTP settings and default workflow scanning with FTP server details</p>

FILEDESC:

PROCESS:

RESOURCE_HW:

TC_WEIGHTAGE: 2.6

APPROVED_SPAR: approved

MDATE: 1544079014

SKILL_SET: intermediate

TESTCASE_SOURCE: feature_spec

TEST_CASE_TYPE: full_test

APPROVE_QE: w4y5hbch

APPROVED_SE: approved

PLANNEDTIMESTAFF:

ATM_OWNER: w4y5hbch

AUTHOR: W44npx4w

IMPLEMENTED: yes

LOE: 60

ASSOCIATED_TESTCASES:

ATM_REQLINK: 17ABDE18-F3EF-11E8-98D2-317FCDD1F86B, 17ACA280-F3EF-11E8-98D2-317FCDD1F86B

TRAINING:

GROUP: device_preparation

MUSER: W44npx4w

SUB_FEATURE:

SPEC_TAG: [22.080.1543] (FT-22840) [D4.0-*] During a SW upgrade to release with higher architecture code (“AAa”), if the revert to previous settings file or the backup file from midnight was created is the same SW version as the desired downgrade version, then a copy of that file will be preserved with a filename that contains the architecture code it was created with.    [22.080.1543.001] (FT-22840) [D4.0-*] During SW downgrade to release with lower architecture code (“AAa”) using customer upgrade methods and Altboot, and a backup file exists that contains the lower architecture code, then device shall automatically restore this backup file.

PROCEDURE: <p>1. Create Folder name "ALTBOOT" and Load the D3.7 build (dlm) without "FORCED_UPGRADE" flag file into the USB. 2. Power off the device and insert the USB and Power on. 3. Upgrade process should continue. 4. Remove the USB when "Software upgrade is completed" and continue the upgrade. 5. Once MFP up</p>, <p>verify the confirmation(1 and 2)</p>, 

RESOURCE_CONSUMEABLES:

ATM_LOCKED: 0

APPROVE_SPAR: w4y5hbch

TESTCASE_PRODUCT:

QA_TEAM:

FILENAME:

ATM_ID: 2F2758E0-F923-11E8-BC3E-DA5C2412F61E

ATM_MCOMMENTS: Copied from "PUQE-CFT_Atlantis_2.0M/Corvo/FS_22.080_Software_upgrade/Common_Testcases/38500".

RESOURCE_MEDIA:

ATM_REQCOUNT: 2