ATM_ID: E3129C3B-6F9E-1014-96AB-CACD56619FB6 ID: PUQE_CFT-Atlantis_1.0/Skylight/FULL/FS_22.080_Software_Upgrade/22315 TESTCASE_HEADLINE: To verify the time taken for the upgrade does not exceed 45 minutes GROUP: FEATURE: SUB_FEATURE: INPUT: Ensure the USB ports are enabled in the device. PROCEDURE: 1. Upgrade the device using Forced Altboot method. 2. Once the device enters Software upgrade screen start the timer. 3. Stop the timer once all the modules upgraded and the progress shows 100%. The variable factors include: • The time taken for the machine to enter upgrade mode • The time taken to transfer the files from the PC via USB to the machine • The time taken to transfer an upgrade file across the network to the Network Controller Disk • Processing (file extraction) time on the machine • Machine reboot time after the upgrade • Disk Encryption OUTPUT: Upgrade time should not exceed more than 45 minutes. PROCESS: PRIORITY: TEST_TYPE: LOE: 20 RESOURCE_HW: RESOURCE_CONSUMEABLES: RESOURCE_MEDIA: SKILL_SET: TEST_CASE_TYPE: TESTCASE_SOURCE: SPEC: [22.080.016] (FT-14502) CCSFEAT21047 CQ507077 [D2.3-*] SPEC_VERSION: 1.0091000000000001 SPEC_TAG: The time taken to program all platforms shall not exceed 45 minutes (excluding variable factors).  ATM_OWNER: ASSOCIATED_TESTCASES: TRAINING: TESTCASE_VERSION: TESTCASE_STATE: TESTCASE_PLATFORM: TESTCASE_PRODUCT: TESTCASE_APPROVALS: CDATE: 1487167874 MDATE: 1487167874 MUSER: w4y5hbch AUTHOR: w4y5hbch ATM_MCOMMENTS: Imported from spreadsheet HISTORY: ATM_LOCKED: ATM_REQLINK: 8099AB6D-6F9A-1014-90F1-D6CF56619FB6 ATM_REQCOUNT: 1 FILENAME: FILEDESC: FILES: QA_TEAM: APPROVE_QE: APPROVED_QE: APPROVE_SE: APPROVED_SE: APPROVE_SPAR: APPROVED_SPAR: MFF: PLANNEDTIMESTAFF: IMPLEMENTED: DATA_LOGIC: AUTOMATABLE_NOTAUTOMATABLE: TC_WEIGHTAGE: