ATM_ID: 152C9FBD-751A-1014-9002-CA0257619FB6 ID: PUQE_CFT-Atlantis_1.0/Snowdon/FULL/FS_22.080_Software_Upgrade/22925 TESTCASE_HEADLINE: To verify that the Nisca IIT Application code is upgradable and assigned version number 150 GROUP: FEATURE: SUB_FEATURE: INPUT: 1. Use device with Nisca scanner installed. 2. Ensure the USB ports are enabled. 3. Use DLM contains upgrade version of IIT App Code (Nisca). PROCEDURE: 1. Perform a USB Forced altboot upgrade . 2. Check the Swupgrade.log file (var/log/swupgrade) after upgrade completed. 3. Check the module ID assigned to Nisca IIT App Code module (via tera term enter cd opt/nc/dlms/upgrade/data/current and then ls). OUTPUT: The device will successfully upgrade Nisca IIT App Code module and it will be assigned number 150. PROCESS: PRIORITY: TEST_TYPE: LOE: 20 RESOURCE_HW: RESOURCE_CONSUMEABLES: RESOURCE_MEDIA: SKILL_SET: TEST_CASE_TYPE: TESTCASE_SOURCE: SPEC: [22.080.1257] (FT-18083) [BI2.0] [+Sn] SPEC_VERSION: 1.0091000000000001 SPEC_TAG: The Nisca IIT application code shall be assigned module number 150.  ATM_OWNER: ASSOCIATED_TESTCASES: TRAINING: TESTCASE_VERSION: TESTCASE_STATE: TESTCASE_PLATFORM: TESTCASE_PRODUCT: TESTCASE_APPROVALS: CDATE: 1487588827 MDATE: 1487588827 MUSER: w4y5hbch AUTHOR: w4y5hbch ATM_MCOMMENTS: Imported from spreadsheet HISTORY: ATM_LOCKED: ATM_REQLINK: 844EC199-74F9-1014-AFFF-F60157619FB6 ATM_REQCOUNT: 1 FILENAME: FILEDESC: FILES: QA_TEAM: APPROVE_QE: APPROVED_QE: APPROVE_SE: APPROVED_SE: APPROVE_SPAR: APPROVED_SPAR: MFF: PLANNEDTIMESTAFF: IMPLEMENTED: DATA_LOGIC: AUTOMATABLE_NOTAUTOMATABLE: TC_WEIGHTAGE: