ATM_ID: 29440E3D-7C37-1014-87F8-A0B01F7BE06D ID: PUQE_CFT/FS_22.020_Installation_and_Configuration_Wizard/9193 TESTCASE_HEADLINE: Billing plan screen content GROUP: device_preparation FEATURE: SUB_FEATURE: PROCEDURE:

1. Before running Install wizard initialize the flag for Billing plan (attach_cc -> '2' for 'Apps Main Menu -> '2' for Diagnostics Admin Test -> 'O' for 'Open Intrusive Diagnostic session' -> '2' for 'NVM Read/Write access' -> '6' for 'Read NVM value by Chain/Link' -> Enter chain as 616 & link as 194 -> Select '1' for Boolean value -> Enter new value as '1'.).
2. Run install wizard (attach_cc -> '2' for 'Apps Main Menu -> Enter 's' -> '3' for 'System Manager Tests -> '2' for 'Install and Configuration menu -> '16' for 'Initialize wizard flags and install phase' - Enter 'Y' -> 'CTRL+d' to 'detach from console screen' -> Reboot.).
3. Proceed till the "Billing Plan screen" and verify the message displayed on the screen.

OUTPUT:

A message should be displayed to the user that the current plan is set to the Default plan of the device.

PROCESS: PRIORITY: 1 TEST_TYPE: manual LOE: 5 RESOURCE_HW: RESOURCE_CONSUMEABLES: RESOURCE_MEDIA: SKILL_SET: intermediate TEST_CASE_TYPE: full_test TESTCASE_SOURCE: SPEC: [22.020.032] (FT-14212) [-Ju] A message shall inform the user that current billing plan is the default plan. SPEC_VERSION: SPEC_TAG: [22.020.032] (FT-14212)_1 ATM_OWNER: y3lzcj6r ASSOCIATED_TESTCASES: TRAINING: TESTCASE_VERSION: TESTCASE_STATE: ready_to_test TESTCASE_PLATFORM: TESTCASE_PRODUCT: atlantis_1.0 TESTCASE_APPROVALS: CDATE: 1466422292 MDATE: 1466422292, 1466588729, 1469628095 MUSER: q50yrg15, q50yrg15, Nishanthan AUTHOR: q50yrg15 ATM_MCOMMENTS: Imported from spreadsheet, RT Mapping done, Updated test procedure HISTORY: ATM_LOCKED: ATM_REQLINK: A57AE5C3-84F8-1014-9190-E67602323758 ATM_REQCOUNT: 1 FILENAME: FILEDESC: FILES: QA_TEAM: APPROVE_QE: Andrew-dc APPROVED_QE: APPROVE_SE: y3lzcj6r APPROVED_SE: approved APPROVE_SPAR: APPROVED_SPAR: MFF: PLANNEDTIMESTAFF: IMPLEMENTED: yes DATA_LOGIC: data AUTOMATABLE_NOTAUTOMATABLE: TC_WEIGHTAGE: 5 INPUT:

Common Precondition:

  1. For all the UI related verifications please refer VBS 22 020 Installation Wizard (http://xww.docushare-xogpsg.world.xerox.com/dsweb/View/Collection-174930).

  2. To iniate Install Wizard in WGC product follow the procedure in “Install_Wizard_Process_WGC products.xlsx” (Available in project server).

  3. To iniate Install Wizard in MC product follow the procedure in “Spyglass_Mfg_Process.docx” (Available in project server).