PRIORITY: TEST_TYPE: APPROVED_QE: INPUT: 1. Printer must be upgraded with the latest build. 2. Connect Device to Teraterm/putty and login as root. FILES: TESTCASE_HEADLINE: Counter Name:Letter (8.5 x 11") Sheets Used Description : Total of 8.5x11" sheets since activation date TESTCASE_VERSION: AUTOMATABLE_NOTAUTOMATABLE: FEATURE: APPROVE_SE: SPEC_VERSION: V2.027 MFF: TESTCASE_PLATFORM: SPEC: FS 34 008 Counters table_XML v2_027 HISTORY: DATA_LOGIC: CDATE: 1578306715 TESTCASE_APPROVALS: TESTCASE_STATE: OUTPUT: The NVM value should be incremented. Note- The increment depends on the number of Sheets. FILEDESC: PROCESS: RESOURCE_HW: TC_WEIGHTAGE: APPROVED_SPAR: MDATE: 1578306715 SKILL_SET: TESTCASE_SOURCE: TEST_CASE_TYPE: APPROVE_QE: APPROVED_SE: PLANNEDTIMESTAFF: ATM_OWNER: AUTHOR: w63LLLNF IMPLEMENTED: LOE: ASSOCIATED_TESTCASES: ATM_REQLINK: TRAINING: GROUP: MUSER: w63LLLNF SUB_FEATURE: SPEC_TAG: S/W Counter Name: LETTER85X11SHEETSUSED PROCEDURE: 1. Steps to Reading NVMS: Type 'attach_cc' --> Click Enter Type (2) for open the apps menu --> Type (2) to enter into Diagnostics Admin Test --> Type (O) To open Intrusive Diagnostics Session --> Type (2) For NVM Read/Write Access --> Type (3) to Read NVM Range by Chain/Link Enter Chain: 606 Starting Link: 208 Ending Link: 208 Note down the NVM value. 2. Perfom 1-sided Black & White copy job use letter media. 3. Follow step 1 again to check the NVM value. RESOURCE_CONSUMEABLES: ATM_LOCKED: 0 APPROVE_SPAR: TESTCASE_PRODUCT: QA_TEAM: FILENAME: ATM_ID: C2B9A110-306F-11EA-BE47-9089B48AF888 ATM_MCOMMENTS: Copied from "PUQE-CFT_Atlantis_2.0-D5.1/FS_34.008_Integrated_Counters_and_Data_Table/40923 Counter Name:Letter (8.5 x 11") Sheets Used Description : Total of 8.5x11" sheets since activation date". RESOURCE_MEDIA: ATM_REQCOUNT: 0