ATM_ID: 00CD1304-1AB9-11F0-8BE4-60BE9352552A MFF: PLANNEDTIMESTAFF: ID: (Trash)/WFAST_NewFeature/D8.5/FT-34698_Accessibility_Speech_Output_EIP/162059 TESTCASE_HEADLINE: To validate that the user shall be notified when their login or logout action has been completed. GROUP: FEATURE: SUB_FEATURE: INPUT: 1. Configure IDP login for the device 2. Speech output should be enabled in the device. 3. Ensure external keyboard is connected with the testing device. 4. Ensure USB ports are enabled in the device. 5. Ensure no card readers/ USB hubs are attached in the device. 6. Ensure no certificates are uploaded in the device. PROCEDURE: 1. In LUI, using external Keyboard, Press Ctrl + 5 to Enable Speech output. 2. In external keyboard -> Press on Home button key -> Navigate to Login button -> Press Enter Key 3. Ensure that the login screen has been opened and shall announce by the Speech Output and Press the skip button to load the microsoft login page. 4. Navigate using tab key, to the Username and Password field, and type the respective username and password in that fields. 5. Ensure that all elements in the Login Screen shall announce by Speech Output. 6. Press Sign in button and ensure that the Login action status shall announce by Speech Output 7. Navigate using Login Button -> Press Enter key -> Navigate to Logout button -> Press Enter key 8. Ensure that the Logout action status shall announce by Speech Output TEST_COVERED_BY: OUTPUT: 3. Speech Output should be provided in focus mode for Login Screens 4. Visual focus indicator should be provided for all the elements in the Login Screen and it should announce by the Speech Output 6. Status message "Login Successful" should be provided and it should announce by the Speech Output 8. Status message "Logout Successful Speech Output Off" should be provided and it should announce by the Speech Output PROCESS: PRIORITY: TEST_TYPE: manual LOE: RESOURCE_HW: RESOURCE_CONSUMEABLES: RESOURCE_MEDIA: SKILL_SET: TEST_CASE_TYPE: TESTCASE_SOURCE: SPEC: FS 51.005 EIP Presentation Services SPEC_NUM: SPEC_VERSION: 1.13.16 SPEC_TAG: [51.005.418] (FT-34698) [PRESSVC] Speech output in Focus Mode shall be provided for login screens. [51.005.419] (FT-34698) [PRESSVC] The user shall be notified when their login or logout action has been completed. ATM_OWNER: APPROVE_QE: APPROVED_QE: APPROVE_SE: APPROVED_SE: APPROVE_SPAR: APPROVED_SPAR: ASSOCIATED_TESTCASES: TRAINING: TESTCASE_VERSION: TESTCASE_STATE: TESTCASE_PLATFORM: TESTCASE_PRODUCT: canyon, carroll, corvo, corrib, kiska, malawi, mystic, melody TESTCASE_FAMILY: TESTCASE_APPROVALS: CDATE: 1744804233 MDATE: 1744804233, 1744812759, 1744875999 MUSER: w4zfpb7v, w4zfpb7v, w4zfpb7v AUTHOR: w4zfpb7v ATM_MCOMMENTS: Imported from spreadsheet, Renamed from "WFAST_Connectivity/Testcases/FS_80.000_Accessibility/162059"., Moved to Trash. HISTORY: ATM_LOCKED: ATM_REQLINK: 8B156FC4-0AED-11F0-8DCD-9ACE7D52552A ATM_REQCOUNT: 1 QA_TEAM: TC_WEIGHTAGE: FILENAME: FILEDESC: FILES: RELEASE: COMPETENCY: AUTOMATION_GROUP: TESTCASE_STEPS_ARE_RELATED_TO: REASON_FOR_AUTOMATABLE: PRECONDITION_TO_BE_DONE: ACTION_TO_BE_DONE: COMMON_FUNCTIONALITY: COMMONALITY_DETAILS: CONSTRAINTS_DAR: DEVELOPMENT_COMPLETE_TIME: PO_SIGNOFF_DATE: COMPLEXITY_PRECONDITIONS: COMPLEXITY_OUTPUT_VALIDATION: AUTOMATABLE: AUTOMATION_CANDIDATE: TESTCASE_MODIFICATION_REQUIRED: APTEST_UPDATE_STATUS: DEVICE_CATEGORY: common TC_WORK_LOCATION_CAT: work_from_office_tc AUTOMATION_TC_VALIDATION: