ATM_ID: 60F7FB84-693F-11F0-90F0-C4D1B6ACCDE0 MFF: PLANNEDTIMESTAFF: ID: Not_to_use_for_any_Dashboard/CCC/165493 TESTCASE_HEADLINE: IOW_FAIL.NC.PRINT GROUP: FEATURE: SUB_FEATURE: INPUT:

Trellix Embedded Control' needs to be 'Disabled' before proceeding with this test case.

PROCEDURE:

1 Submit the print job SCAN-SMALL.pdf from the Web UI following the steps described in procedure CO_JOBSUBMIT_PRINT_WEB.

2 From the network controller serial terminal window,login to the network controller. Execute the following command to cause a network controller overwrite error:

rm /var/spool/nc/net/*.1
3 Verify the {LUI OVERWRITE SECURITY FAILURE ERROR MESSAGE} is displayed and error sheet prints.
4 Follow the steps indicated in procedure CO_JOBSTATUS_COMPLETEDJOBLOG to view the 'Immediate Overwrite' status in the {LUI ALL COMPLETED JOBS WINDOW} from the Local UI for the print job.
5 Verify audit entry following steps in CO_JOBSTATUS_AUDITEVENTS.
6 Follow the steps indicated in procedure CO_ODIO_INVOKE_LUI to initiate an On Demand Image Overwrite from the Local UI. Allow the On Demand Image Overwrite to complete,and for the machine to reboot the software and come back on-line.

TEST_COVERED_BY: SRT_ANALYZATION: OUTPUT:

See Procedure CO_JOBSUBMIT_PRINT_WEB.

  1. The {LUI OVERWRITE SECURITY FAILURE ERROR SCREEN} will be displayed on the Local UI.
  2. An {IMMEDIATE IMAGE OVERWRITE ERROR SHEET} will be printed.
    The text will be displayed: “Immediate Job Overwrite Failed. Perform an On Demand Overwrite Immediately”. An error sheet will also be printed.
    The 'Immediate Overwrite' field should show 'Unsuccessful'.
    See CO_JOBSTATUS_AUDITEVENTS
  3. Event '5 Print Job' will be recorded.
  4. IIO status will be "IIO-failed".
  5. The time-stamp will be the time the error is displayed to the LUI.
    An {ON DEMAND OVERWRITE CONFIRMATION REPORT} will print with a 'Job Status" of 'SUCCESS'.
PROCESS: PRIORITY: TEST_TYPE: LOE: RESOURCE_HW: RESOURCE_CONSUMEABLES: RESOURCE_MEDIA: SKILL_SET: TEST_CASE_TYPE: TESTCASE_SOURCE: SPEC: SPEC_NUM: SPEC_VERSION: SPEC_TAG: ATM_OWNER: APPROVE_QE: APPROVED_QE: APPROVE_SE: APPROVED_SE: APPROVE_SPAR: APPROVED_SPAR: ASSOCIATED_TESTCASES: TRAINING: TESTCASE_VERSION: TESTCASE_STATE: TESTCASE_PLATFORM: TESTCASE_PRODUCT: TESTCASE_FAMILY: TESTCASE_APPROVALS: CDATE: 1753438137 MDATE: 1753438137 MUSER: USWU53416 AUTHOR: USWU53416 ATM_MCOMMENTS: Imported from spreadsheet HISTORY: ATM_LOCKED: ATM_REQLINK: ATM_REQCOUNT: 0 QA_TEAM: TC_WEIGHTAGE: FILENAME: FILEDESC: FILES: RELEASE: COMPETENCY: AUTOMATION_GROUP: TESTCASE_STEPS_ARE_RELATED_TO: REASON_FOR_AUTOMATABLE: PRECONDITION_TO_BE_DONE: ACTION_TO_BE_DONE: COMMON_FUNCTIONALITY: COMMONALITY_DETAILS: CONSTRAINTS_DAR: DEVELOPMENT_COMPLETE_TIME: PO_SIGNOFF_DATE: COMPLEXITY_PRECONDITIONS: COMPLEXITY_OUTPUT_VALIDATION: AUTOMATABLE: AUTOMATION_CANDIDATE: TESTCASE_MODIFICATION_REQUIRED: APTEST_UPDATE_STATUS: DEVICE_CATEGORY: TC_WORK_LOCATION_CAT: AUTOMATION_TC_VALIDATION: