ATM_ID: 60984412-BF3E-11ED-A970-06C91B54DFD1
MFF:
PLANNEDTIMESTAFF:
ID: WFAST_Accounting/Testcases/FS_18.051_Job_Limits/119602
TESTCASE_HEADLINE: To check if the Job Monitor is not currently displayed/active,then the system / inactivity timer shall be active (if enabled) when displaying the Communication Error Screen.
GROUP:
FEATURE:
SUB_FEATURE:
INPUT:
Make sure the device should be in the latest build.
PROCEDURE:
- In WebUI,login as Admin.
- Go to Properties-- Login/Permissions/Accounting-- Accounting Methods-- Edit Accounting Methods-- Select Network Accounting under Current Accounting Method-- Save.
- Edit Accounting Workflow-- Change the Accounting Workflow from 'Capture Usage' to 'Pre-Authorization and Capture Usage' for Print Job.
- Edit Job Limit Server-- Print (http://eipappserver1.sdsp.mc.xerox.com/JobLimitsTest/JobLimitsServer.asmx) as URL-- Give some value as timeout like 30 seconds-- Save. Note: Access Config Tool should be there.
- Go to Properties-- Security-- Timeout & Resume-- Set few seconds ie less than the time set for JobLimits for 'Touch User Interface System Timeout' -- Save.
- In LUI,perform a Print Job-- 'Authorizing' Screen is displayed each time with the corresponding Job ID.
- Do not respond to the corresponding print job from the lob limit server and Wait till the device can contact the job limit server twice as per the time out period set
- Once the device reaches configured time out period check if "Communication Error" screen is displayed
- Make no change in the LUI
OUTPUT:
- Communication Error screen should be displayed once the device reaches the configure timeout period 2. Inactivity timer pop up should be displayed on top of Communication Error screen when Inactivity timer is expired
PROCESS:
PRIORITY:
TEST_TYPE: manual
LOE:
RESOURCE_HW:
RESOURCE_CONSUMEABLES:
RESOURCE_MEDIA:
SKILL_SET:
TEST_CASE_TYPE: testcases
TESTCASE_SOURCE:
SPEC: FS_18.051_Job_Limits
SPEC_NUM:
SPEC_VERSION:
SPEC_TAG: 18.051.065
ATM_OWNER:
APPROVE_QE:
APPROVED_QE:
APPROVE_SE:
APPROVED_SE:
APPROVE_SPAR:
APPROVED_SPAR:
ASSOCIATED_TESTCASES:
TRAINING:
TESTCASE_VERSION:
TESTCASE_STATE:
TESTCASE_PLATFORM:
TESTCASE_PRODUCT: canyon, carroll_mfp, carroll_sfp, corvo, corrib, kiska, malawi, mystic, melody_sfp, melody_mfp, muckross
TESTCASE_FAMILY:
TESTCASE_APPROVALS:
CDATE: 1678451014
MDATE: 1678451014
MUSER: USWU60000
AUTHOR: USWU60000
ATM_MCOMMENTS: Imported from spreadsheet
HISTORY:
ATM_LOCKED:
ATM_REQLINK: 84E54E26-902D-1014-B25E-83F639A0A0FC
ATM_REQCOUNT: 1
QA_TEAM:
TC_WEIGHTAGE:
FILENAME:
FILEDESC:
FILES:
RELEASE:
COMPETENCY: wfast_accounting
AUTOMATION_GROUP:
TESTCASE_STEPS_ARE_RELATED_TO:
REASON_FOR_AUTOMATABLE:
PRECONDITION_TO_BE_DONE:
ACTION_TO_BE_DONE:
COMMON_FUNCTIONALITY:
COMMONALITY_DETAILS:
CONSTRAINTS_DAR:
DEVELOPMENT_COMPLETE_TIME:
PO_SIGNOFF_DATE:
COMPLEXITY_PRECONDITIONS:
COMPLEXITY_OUTPUT_VALIDATION: non_outliers
AUTOMATABLE: no
TESTCASE_MODIFICATION_REQUIRED:
APTEST_UPDATE_STATUS:
DEVICE_CATEGORY: sfp
TC_WORK_LOCATION_CAT: work_from_home_tc
AUTOMATION_TC_VALIDATION:
AUTOMATION_CANDIDATE: yes
SRT_ANALYZATION: analyzed